Building height and number of stories: grade plane (Tables 504.3/504.4)
One-line orientation
Occupancy, construction type, and sprinklers set a building’s allowable height and number of stories. Both are measured from the grade plane. On a sloped site, identify the correct measurement point. Taller buildings generally need more fire-resistive construction.
Key points
- Two separate limits, two tables:
- Table 504.3 — allowable building height in feet.
- Table 504.4 — allowable number of stories.
- The design must satisfy both at once.
- Three inputs drive both lookups: occupancy group, construction type, and whether the building is sprinklered.
- How height is measured: from the grade plane to the average height of the roof surface (the mid-height of a sloped or pitched roof, not the ridge).
- Grade plane on a sloped site: use the average finished ground level adjoining all exterior walls. It is not simply the midpoint between one high point and one low point.
- Tall buildings force a high construction type:
- A very tall residential tower — say 310 ft — can only be built as Type I-A, which carries unlimited height.
- For R-2 (apartments), Type I-B tops out at 180 ft / 12 stories (sprinklered, Tables 504.3/504.4) — anything taller is Type I-A only.
Confusions / comparison
| Table 504.3 | Table 504.4 | |
|---|---|---|
| Limits | Height in feet | Number of stories |
| Same inputs | Occupancy + construction type + sprinklers | Occupancy + construction type + sprinklers |
| Must satisfy | Yes | Yes — both, independently |
| Height measurement | Grade plane on a slope | |
|---|---|---|
| Top reference | Average roof height (mid-height of slope) | — |
| Bottom reference | Grade plane | Average finished ground level adjoining the exterior walls |
| Common error | Measuring to the ridge | Using lowest (or highest) grade alone |
Related
→ Allowable area: occupancy × construction type × sprinklers (this module): the area side of the same Chapter 5 analysis · Area increases: frontage and sprinkler (this module): sprinklers also raise height/story limits · Construction types (this module): why Type I-A buys unlimited height.
Spotted an issue with this card? Tell us →