Sheet LS-115
Egressconcept
Egress doors: swing, hardware, operability
One-line orientation
An egress door must let people leave without a key, tool, or special knowledge. When the code’s occupant-load or hazard triggers apply, it must also swing in the direction of egress travel.
Key points
- Swing direction: egress doors swing in the direction of egress travel so occupants pushing toward the exit can’t bind the door shut. Triggered at an occupant load of 50 or more served by the door, or any Group H occupancy.
- Operability from the egress side: the door must be openable without a key, tool, special knowledge, or special effort, in a single releasing motion. This applies to all doors in the egress path.
- Panic hardware: push-bar hardware that releases on a single push; required on latched doors serving Group A or E spaces with an occupant load of 50 or more, and in Group H. On fire-rated doors the listed equivalent is fire exit hardware.
- Swing intrusion: an open or swinging door must not block more than half the required egress width, and a fully open door must not project more than 7 inches into it.
- Width/landings: the door’s clear opening and its level landings must preserve the required egress width on both sides.
Confusions / comparison
| Aspect | Egress requirement | Trap the exam sets |
|---|---|---|
| Swing direction | In the direction of travel (out) at 50+ occupants (or Group H) | “Doors always swing out” — only required at the load threshold |
| Egress-side operation | No key, tool, or special knowledge; single motion | A keyed deadbolt or thumb-turn-plus-latch that needs two actions |
| Panic hardware | Required for Group A/E rooms or spaces at OL ≥ 50 and Group H; fire exit hardware if the door is fire-rated | Assuming every commercial or rated door needs a panic bar |
| Swing intrusion | Cannot block more than half the required width | Ignoring how far the leaf projects into the corridor |
| Locked side | May be locked from outside (security) | Confusing “lockable from outside” with “can lock people in” |