Sheet A-103
Enclosureconcept
Vapor retarders: perm classes and climate-based placement
One-line orientation
Vapor retarders are generally placed toward the warm, humid side of an assembly, but the final class and location depend on the climate and wall design.
Key points
- Job: slow vapor diffusion so moisture doesn’t reach a surface at or below the dew point and condense inside the assembly (which causes mold and rot).
- Three perm classes (lower perm = tighter):
- Class I — impermeable, ≤ 0.1 perm: aluminum foil, thick (≥6-mil) polyethylene. For very cold or very high-humidity conditions needing maximum control.
- Class II — semi-impermeable, >0.1–1.0 perm: plywood, kraft paper, some thick rigid foam. Appropriate in some assemblies; climate alone does not make it the automatic mixed-climate answer.
- Class III — semi-permeable, >1–10 perms: latex/enamel paint over gypsum. For mild/dry climates where drying potential matters more than resistance.
- Placement by climate (the rule that flips):
- Cold climate → interior (warm) side, to stop warm indoor air from reaching cold exterior surfaces.
- Hot/humid climate → exterior (warm) side, to block humid outdoor air from infiltrating the cooler interior.
- Mixed climate → choose vapor control from the whole assembly and its drying path. Class II is not an automatic answer.
- Supporting concepts: relative humidity (moisture vs. the air’s max at that temperature), dew point (saturation/condensation temperature), condensation (moist air cooled below dew point).
Confusions / comparison
| Perm class | Permeance | Behavior | Example materials | Best for |
|---|---|---|---|---|
| Class I | ≤ 0.1 perm | Impermeable (true vapor barrier) | Aluminum foil, ≥6-mil poly | Very cold / high-humidity |
| Class II | >0.1 – 1.0 perm | Semi-impermeable | Plywood, kraft paper, some thick rigid foam | Some assemblies; climate-specific |
| Class III | >1 – 10 perms | Semi-permeable | Latex/enamel paint over gypsum | Mild / dry climates |
| Climate | Vapor retarder side | Reason |
|---|---|---|
| Cold | Interior (warm side) | Keep warm moist indoor air off cold exterior surfaces |
| Hot / humid | Exterior (warm side) | Block humid outdoor air from the cool interior |
| Mixed | Assembly-specific | Select the class and location to preserve the intended drying path |